Instructions for Ecoflam gas burners. Instructions for gas burners Ecoflam Gas burner blu
Gas burners of the MAX GAS 40 P, MAX GAS 70 P, MAX GAS 105 P, MAX GAS 120 P series. Installation and operating instructions. Language: RU, EN, IT, FR, ES | pdf 7.77 Mb
Gas burners series MAX GAS 170 P MAX GAS 250 P. Installation and operating instructions. Language: RU, EN, IT, FR, ES | pdf 5.20 Mb
Gas burners series MAX GAS 170-250 P-PAB Low Nox. Instructions for installation, operation and service. Language: RU, EN, IT, FR, ES | pdf 5.89 Mb
Gas burners series MAX GAS 350-500 PR Low Nox. Instructions for installation, operation and service. Language: RU, EN, IT, FR, ES | pdf 7.65 Mb
Gas burners of the MAX GAS 40, MAX GAS 70, MAX GAS 105, MAX GAS 120 P Low Nox Biogas series. Instructions for installation, operation and service. Language: RU, EN, IT, FR, ES | pdf 4.49 Mb
Gas burners of the MAX GAS 70, MAX GAS 105, MAX GAS 120 PAB Low Nox series. Instructions for installation, operation and service. Language: RU, EN, IT, FR, ES | pdf 3.28 Mb
Gas burners series MAX GAS 350-500 P-PAB Low Nox. MAX GAS 350, MAX GAS 350 P AB, MAX GAS 500 P, MAX GAS 500 P AB Low Nox. Instructions for installation, operation and service. Language: RU, EN, IT, FR, ES | pdf 7.11 Mb
Gas burners of the BLU 350.1 PR, BLU 400.1 PR series. Installation and operation instructions. Language: RU | pdf 803.73 Kb
Gas burners series BLU 500.1 P AB, BLU 700.1 P AB, BLU 1000.1 P AB, BLU 1200.1 P AB. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 4.10 Mb
Gas burners of the BLU 500.1 PR, BLU 700.1 PR, BLU 1000.1 PR, BLU 1200.1 PR Low NOx series. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 3.02 Mb
Gas burners BLU 1500.1 P AB series. Installation and operation instructions.
Gas burners series BLU 1700.1 P AB, BLU 2000.1 P AB. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 3.44 Mb
Gas burners series BLU 3000.1 PR, BLU 4000.1 PR. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 5.49 Mb
Gas burners of the BLU 500.1 P, BLU 700.1 P Low Nox series. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 3.10 Mb
Gas burners series BLU 500.1 PR, BLU 700.1 PR, BLU 1000.1 PR, BLU 1200.1 PR. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 3.23 Mb
Gas burners of the BLU 500.1 PR, BLU 700.1 PR, BLU 1000.1 PR, BLU 1200.1 PR SW series. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 4.53 Mb
Gas burners BLU 1500.1 PR series. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 2.91 Mb
Gas burners series BLU 1700.1 PR, BLU 2000.1 PR. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 3.37 Mb
Two-stage gas burners of the BLU 3000.1 PR/MD DUO, BLU 4000.1 PR/MD DUO series. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 4.12 Mb
Gas blast burners of the BLU 7000.1 PR, BLU 8000.1 PR, BLU 10000.1 PR, BLU 12000.1 PR series. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 4.70 Mb
Gas burners series BLU 7000.1 MD, BLU 8000.1 MD, BLU 10000.1 MD, BLU 12000.1 MD LMV version. Installation and operation instructions. Language: RU | pdf 835.08 Kb
Two-stage gas burners series BLU 7000.1 PR/MD DUO, BLU 8000.1 PR/MD DUO, BLU 10000.1 PR/MD DUO, BLU 12000.1 PR/MD DUO. Installation and operation instructions. Language: RU | pdf 4.58 Mb
Gas blast burners of the BLU 15000.1, BLU 18000.1 PR/PR TS series. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 2.34 Mb
Gas burners series BLU 23000.1 PR TS, 25000.1 PR TS. Installation and operation instructions. Language: RU, EN, IT, FR, ES | pdf 2.49 Mb
- Gas burners ECOFLAM Blu. Main characteristics.
- Housing in aluminum for models up to Blu 2000.1 and in steel from Blu 3000.1 onwards, with integrated control panel as standard with degree of protection IP40. On request, burners without a remote control or with a remote control with degree of protection IP54.
- Powerful fan, designed to ensure flame stability, easily compatible with various types of boilers.
- The adjustable fire head makes it easy to adjust the burner to suit different combustion chambers.
- Easy to maintain - access to the fire head without removing the burner from the boiler.
- Low NOx version, class 3 according to EN 676 The two-stage burners from Blu 500.1 to Blu 2000.1 feature a new, fast and simple gas flow control system using a butterfly valve.
- In PR and MD burners there is an adjustable position of the fire head with a working regulation ratio of 1:5 ( standard coefficient working regulation 1:3).
- Models with power modulation are equipped with a PID controller with a digital display that shows actual parameter values and allows you to change setpoints.
- Burners with smooth switching from low to high combustion are equipped with a system for fine adjustment of gas flow, which includes an electric drive with a high gear ratio and an adjusting bar of variable geometry.
- Models with variable flame geometry (on request).
- Burners of the Duoblock series (industrial block burners) with a power range of 180 - 25000 kW.
- Burners with continuous ventilation for all models (on request).
- Burners available for LIQUEFIED GAS, BIOGAS and CITY GAS (on request).
- Special burner versions for different applications on different types fuel (on request).
MODELS | Thermal power | Thermal power | Gas pressure | Power supply | Engine power | Class | Modification | ||
kW | kcal/hour x 1000 | kW | kcal/hour x 1000 | mbar | IN | kW | NOx | ||
BLU 350.1 Low NOx | 350 | 301 | 100 | 126,42 | 17 500 | 230 | 0,3 | 3 | P-P AB-PR |
BLU 400.1 | 400 | 345 | 100 | 126,42 | 18 500 | 230 | 0,3 | 2 | P-P AB-PR |
BLU 500.1 Low NOx | 500 | 430 | 220 | 189,6 | 17 - 500 | 230/400 | 0,55 | 3 | P AB-PR-MD |
BLU 500.1 | 500 | 430 | 180 | 155,2 | 15 - 500 | 230/400 | 0,55 | 2 | P AB-PR-MD |
BLU 700.1 Low NOx | 700 | 602 | 270 | 232,2 | 15 - 500 | 230/400 | 0,74 | 3 | P AB-PR-MD |
BLU 700.1 | 700 | 602 | 225 | 194 | 15 - 500 | 230/400 | 0,74 | 2 | P AB-PR-MD |
BLU 1000.1 Low NOx | 875 | 752,5 | 280 | 240,8 | 30 - 500 | 230/400 | 1,1 | 3 | P AB-PR-MD |
BLU 1000.1 | 970 | 836,2 | 245 | 211,2 | 25 - 500 | 230/400 | 1,1 | 2 | P AB-PR-MD |
BLU 1200.1 Low NOx | 1.100 | 946 | 290 | 249,4 | 20 - 600 | 230/400 | 2,2 | 3 | P AB-PR-MD |
BLU 1200.1 | 1.200 | 1034,5 | 260 | 224,14 | 25 - 600 | 230/400 | 2,2 | 2 | P AB-PR-MD |
BLU 1500.1 Low NOx | 1.550 | 1336,2 | 300 | 259 | 30 - 700 | 230/400 | 3 | 3 | P AB-PR-MD |
BLU 1700.1 | 1.770 | 1.526 | 342 | 295 | 20 - 700 | 230/400 | 3 | 2 | P AB-PR-MD |
BLU 2000.1 | 2.150 | 1.853,45 | 414 | 356,9 | 23 - 700 | 230/400 | 4 | 2 | P AB-PR-MD |
BLU 3000.1 | 3.000 | 2.586 | 630 | 543,1 | 22 - 700 | 230/400 | 5,5 | 2 | PR-MD |
BLU 4000.1 | 3.900 | 3.362 | 875 | 754,3 | 30 - 700 | 230/400 | 7,5 | 2 | PR-MD |
BLU 5000.1 | 5.000 | 4.310 | 1.200 | 1.034,5 | 35 - 700 | 230/400 | 11 | 2 | PR-MD |
BLU 6000.1 | 5.800 | 5.000 | 1.500 | 1.290 | 50 - 700 | 230/400 | 15 | 2 | PR-MD |
BLU 7000.1 | 7.500 | 6.465 | 1.500 | 1.290 | 60 - 700 | 230/400 | 15 | 2 | PR-MD |
BLU 8000.1 | 8.500 | 7.327,5 | 2.000 | 1.724 | 85 - 700 | 230/400 | 18,5 | 2 | PR-MD |
BLU 10000.1 | 10.500 | 9.052 | 2.500 | 2.155 | 115 - 700 | 230/400 | 22 | 2 | PR-MD |
BLU 12000.1 | 13.000 | 11.207 | 2.700 | 2.327,6 | 160 - 700 | 230/400 | 37 | 2 | PR-MD |
BLU 15000.1 | 15.000 | 12.931 | 3.690 | 3.181 | 125 - 700 | 230/400 | 45 | 2 | PR-MD |
BLU 18000.1 | 17.000 | 14.655 | 4.000 | 3.448,27 | 175 - 700 | 230/400 | 55 | 2 | PR-MD |
Type of fuel: Natural gas(lower calorific value. 8.570 kcal/Nm3), liquefied. gas (lower calorific value 22.260kcal/Nm3)
|
Italian Ecoflam BLU gas burners are supplied complete with a gas train. From us you can buy an Ecoflam BLU burner with a short or long flame head, modulated or two-stage power control. Suitable for boilers, heat generators, furnaces, dryers and other technological units
Advantages of Ecoflam Blu gas burners
Burner range
Blu model burners can operate on natural or liquefied gas, necessary equipment To reconfigure the system, it is supplied upon customer request. Devices of this type have three designs:
- PAB is a two-stage system designed to operate in one of two fixed modes with a given fuel consumption. Switching is carried out manually or automatically.
- PR is a two-stage unit with a smooth change in gas supply parameters. The device is controlled using a mechanical device.
- MD - modulated system. The burner is controlled using an electronic device, a PID controller.
Technical characteristics of gas burners
Blu gas burners are modular universal designs adapted for use in industrial enterprises And civilian objects. Basic specifications depend on the product model and range from:
- rated thermal power - from 17 to 25,000 kW;
- gas consumption - from 15.5 to 175.7 kg/h;
- consumed electrical power - from 0.48 to 55 kW.
Burners gas type Blu are equipped with supercharging equipment that can operate in single- and three-phase networks with voltages of 220 and 380 V. The products belong to the second and third classes of NOx, which ensures minimal emissions in environment in accordance with the requirements of the EN676 standard.
Blu burners delivery set
Gas burners of the Blu model are supplied to the customer in the following configuration:
- Burner body with long TL or short flame head TC.
- A silencer is included in the equipment for models 3000.1 and above; for products of lower power at the request of the Customer.
- Separate gas train.
- Gas pressure stabilizer or filter and gas pressure stabilizer.
- Gas filter.
- Maximum gas pressure switch.
- Leak testing device.
Characteristics of Ecoflam BLU gas burners
Housing in aluminum up to Blu 4000.1 and steel from Blu 5000.1, integrated control panel.
Powerful fan, designed to ensure flame stability, easily compatible with various types of boilers.
The adjustable fire head makes it easy to adjust the burner to suit different combustion chambers.
Low NOx version - Blu 500.1 to Blu 1400.1 (< 80 мг/кВтч).
The two-stage burners from Blu 500.1 to Blu 2000.1 feature a new, fast and simple gas flow control system using a throttle valve.
Burners with smooth switching from low to high combustion are equipped with a system for fine adjustment of gas flow, which includes an electric drive with a high gear ratio and an adjusting bar of variable geometry.
Models with power modulation are equipped with a PID controller with a digital display that shows actual parameter values and allows you to change setpoints.
Automatic system for adjusting the primary air flow depending on the required power, starting with the Blu 7000.1 model.
Easy to maintain - access to the fire head without removing the burner from the boiler.
Available on special order: models with variable flame geometry.